This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
start [2025/09/18 14:37] 172.71.170.116 old revision restored (2025/09/18 09:27) |
start [2025/09/18 14:37] (current) 172.68.27.192 old revision restored (2025/09/18 09:27) |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ==== Overview ==== | + | **Overview** |
- | + | ||
- | The Merlin AutoGC Xplorer (**MAX**) is a cloud-based database designed to ingest data generated by chromatographic equipment deployed into EPA Photochemical Assessment Monitoring Sites (**PAMS**) which are collecting and analyzing hourly concentrations of up to 60 volatile organic compounds (**VOC**). | + | |
- | Orsat, LLC has developed and designed MAX to accommodate data originating from either PerkinElmer Ozone Precursor systems or Agilent systems using Markes International pre-concentration sampling system. | + | Now is the time for all good men to come to the aid of their country. |
- | ==== Features ==== | + | |
+ | ====== Operator rights are different ====== | ||
- | The PAMS AutoGC systems collect not only hourly ambient air data but also have Quality Control samples which are outlined in the EPA PAMS Technical Assistance Guidance document (**TAD**). | + | |
- | === Quality Control Sample Types === | + | |
- | - Calibration Verification Standard (CVS) or Continuing Calibration Verification (CCV) Standard | + | |
- | * Required daily | + | |
- | * Used to confirm system response daily; recoveries generally ± 30% specified in the Network configuration | + | |
- | - System Blank (SB) or Method Blank | + | |
- | * Required daily | + | |
- | * Used to determine concentrations of target compounds which may be contributed by the analytical system | + | |
- | - Laboratory Calibration Standard (LCS) or Second Source Calibration Verification (SSCV) Standard | + | |
- | * Required weekly | + | |
- | * Used to confirm original calibration by reference. | + | |
- | - Retention Time Standard (RTS) | + | |
- | * Required weekly | + | |
- | * Used to verify correct target identification by retention time windows in method. | + | |
- | | ||
- | === Format for Incoming Data - ASCII Text === | ||
- | The output format for data generated by the analytical data system must adhere to a specific ASCII text format to enable MAX to be able to correctly interpret and store the data. Orsat has generated output formats for both the Totalchrom and EZChrom data systems. | ||
- | |||
- | * Instrument Name - (Format " | ||
- | * Filename - specific format (see File Naming) | ||
- | * Acquisition Time - the time the analytical data collection started. | ||
- | * Process Date and time- the time the data file was generated | ||
- | * Sample Name, generally Blank, Standard, Ambient Air, IQ-RTS, CS-LCS | ||
- | * Instrument Name | ||
- | * Instrument method filename | ||
- | * Sequence filename | ||
- | * Peak Details | ||
- | * Component Name | ||
- | * Amount in ppbC | ||
- | * Retention time | ||
- | * Peak Area | ||
- | |||
- | MAX was designed to identify the QC control samples by using a specific file naming paradigm. | ||
- | |||
- | // | ||
- | FIlenameStructure 2.png// | ||
- | |||
- | | ||
- | |||
- | |||
- | |||
- | |||
- | ==== Network and Site Configuration ==== | ||
- | |||
- | In order to allow the evaluation of these QC samples each data set or //Site// has a definition which incorporates configuration parameters for the //Network// which defines information about incoming data such as a list of target VOCs, which targets will be in the QC samples and their concentrations and control limits. | ||
- | === Information Required for Network Configuration === | ||
- | |||
- | - Units (default is ppbC) | ||
- | - How Lost data will be displayed | ||
- | - How zero values will be displayed | ||
- | - Total Blank Maximum value | ||
- | - List of Target Compounds by Channel | ||
- | - List of Target Compounds in each of the required QC samples (LCS, CVS, RTS, Blank and MDL) including required control limits | ||
- | - List of applicable Null, Qualifier and Inform Flags available for use in AQS files. | ||
- | |||
- | Each Site also has unique information to identify it in the database. | ||
- | |||
- | === Information Required for Site Configuration === | ||
- | |||
- | - Site name (defined in the incoming ASCII text file as " | ||
- | - Type - designation of data system generating the data, PerkinElmer or EZChrom | ||
- | - Minimum display value - generally 0 | ||
- | - Network assigned to the site | ||
- | - AQS number assigned to the site | ||
- | - POC if necessary | ||
- | - Short name - user entered text field | ||
- | - Formal name - user entered text field | ||
- | - Address, City and Zipcode | ||
- | - Latitude and Longitude | ||
- | - UTC offset | ||
- | - CAMS code (if available) | ||
- | - Interval, units code and method codes required for AQS file generation | ||
- | |||
- | ==== Site Permissions ==== | ||
- | MAX allows for user-defined permissions for each user based on the users role. These roles define the activities available to that user. Users can be designated as Administrators, | ||
- | === Roles === | ||
- | * __Guest__ - viewing access only, no access to raw TX0 data, Screening tools, Generation of CSV output, AQS Files. | ||
- | * __Operators__ - Same as Guest. Additional access to view TX0 data, generate CSV output and the ability to add or edit Certificates of Analysis, QA/QC table updates, and Site Information | ||
- | * __Validators__ - Same as Operators with added ability to add or edit all features. | ||
- | * __Admin__ - full access to all functions | ||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | |||
- | ---- | ||
- | |||
- | **References** | ||
- | |||
- | EPA Technical Assistance Document (TAD) | ||
- | ---- | ||
- | https:// | ||
- | ---- | ||