User Tools

Site Tools


start

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
start [2025/04/03 04:23]
162.158.174.184 old revision restored (2025/03/29 02:44)
start [2025/04/04 00:16] (current)
172.71.166.73 old revision restored (2021/10/18 19:59)
Line 25: Line 25:
  QC.png - I don't have rights to upload documents.  QC.png - I don't have rights to upload documents.
 === Format for Incoming Data - ASCII Text === === Format for Incoming Data - ASCII Text ===
-The output format for data generated by the analytical data system must adhere to a specific ASCII text format to enable MAX to be able to correctly interpret and store the data.  Orsat has generated output formats for both the Totalchrom and EZChrom data systems.  The user will not only need this format for the output but will need their analytical method to adhere to specific requirements such as target names, response factor format and calibration units.  Orsat can assist by supplying methods for each analytical and help the user to implement any necessary changes that might be required.  +The output format for data generated by the analytical data system must adhere to a specific ASCII text format to enable MAX to be able to correctly interpret and store the data.  Orsat has generated output formats for both the Totalchrom and EZChrom data systems.  The user will not only need this format for the output but will need their analytical method to adhere to specific requirements such as target names, response factor format and calibration untis.  Orsat can assist by supplying methods for each analytical and help the user to implement any necessary changes that might be required.   
- +**Required Input from Analytical System**
     * Instrument Name - (Format "SITE-//x//")     * Instrument Name - (Format "SITE-//x//")
     * Filename - specific format (see File Naming)     * Filename - specific format (see File Naming)
Line 43: Line 43:
 MAX was designed to identify the QC control samples by using a specific file naming paradigm.  Thus filenames must be specific to the sample type.  Filenames are generated using a sequence generator which assigns filenames and schedules the necessary QC samples in the analytical system.  This requires specific automation not generally provided as part of the original manufacturers product.  Orsat offers the necessary hardware and software to generate not only the sequences with descriptive filenames but also the hardware to automate the introduction of the necessary QC samples for both the PerkinElmer and Agilent systems. MAX was designed to identify the QC control samples by using a specific file naming paradigm.  Thus filenames must be specific to the sample type.  Filenames are generated using a sequence generator which assigns filenames and schedules the necessary QC samples in the analytical system.  This requires specific automation not generally provided as part of the original manufacturers product.  Orsat offers the necessary hardware and software to generate not only the sequences with descriptive filenames but also the hardware to automate the introduction of the necessary QC samples for both the PerkinElmer and Agilent systems.
  
-//FilenameStructure 1.png +Filename structure.png
-FIlenameStructure 2.png//+
  
-    +      
  
  
Line 61: Line 60:
   - Total Blank Maximum value   - Total Blank Maximum value
   - List of Target Compounds by Channel   - List of Target Compounds by Channel
-  - List of Target Compounds in each of the required QC samples (LCS, CVS, RTS, Blank and MDLincluding required control limits+  - List of Target Compounds in each of the required QC samples (LCS, CVS, RTS, Blank and MDL by channel including required limits or thresholds
   - List of applicable Null, Qualifier and Inform Flags available for use in AQS files.   - List of applicable Null, Qualifier and Inform Flags available for use in AQS files.
  
-Each Site also has unique information to identify it in the database.  In addition to a unique site name other information is required to generate a site-specific AQS data file which will be submitted to the EPA AQS Database.+Each Site also has unique information to identify it in the database.  In addition to a  specific 
  
 === Information Required for Site Configuration === === Information Required for Site Configuration ===
start.1743654239.txt.gz · Last modified: 2025/04/03 04:23 by 162.158.174.184 · Currently locked by: 172.71.167.113,20.171.207.118